The CūrPod System is a hermetically sealed enclosure with a stainless steel base and a clear molded cover that sits in a channel for perfect sealing. It has a capacity for approximately 20 pounds of product in four standard 15.5 x 23.5 x 7.75 inch plastic crates.
Each pod is self-contained with built in Oxygen, Carbon Dioxide, temperature and Relative Humidity sensors with digital communications to a central operating panel. Built in control valves and gauges regulate the connected Nitrogen, Air, or CO2 supply to accurately maintain the programmed levels. A patent-pending respiration technology automatically indicates dry and cure status.
FEATURES
Patent-Pending Dry Cure Status using Respiration Data Expands on Our Patented Technology -
U.S. Patent No. 8739694, Canadian Patent No. CA2746152 for Large Dry Rooms
Self-Contained Control of Low O2 Atmosphere
for Long Term Holding
Built-In High-Resolution Gas Analysers
Automatic Operation & Full Data Recording
Moisture Sensors for Precise & Consistent Moisture Content in Final Product (Coming Soon)
Hydrate Dry Product
Introduce TerpenesBreakdown chlorophyll and sugars, not terpenes More time growing; less time curing
Reduce microbial contamination
Increase average cost per pound
Easily maintain fresh drop flavor for up to 12 months Consistent cure process
MEASUREMENT & CONTROL RANGE
Oxygen: 0-25% or 0-2.5% Auto range Resolution: low range +/- 0.002% O2 Electrochemical 4-year long life sensor
Carbon Dioxide: Two options at purchase, 0-50000 ppm or 0-20% CO2 Resolution: < 5% 0.002% >5% 0.02%
CONTROL INPUTS
Control Gases required: Nitrogen with an oxygen content lower than minimum required CA Oxygen.
Fresh Filtered Air. CO2 if required. Gas supply inlet pressure 1 to 3 Bar (15 to 50 psi )
Automatic atmosphere control with included solenoids.
Control Setpoints for Oxygen and CO2 adjustable to a 0.01% resolution. Gas control differentials 0.05%, CO2 add differential 0.2%.
Air added when Oxygen is measured low: Air flow adjustable 0.1 to 1 L/min
Nitrogen added when Oxygen is measured high or when CO2 is high. Adjustable flow 0.2 to 2 L/min
CO2 (if connected) added when CO2 is low. Adjustable flow 20 to 200 mL/min.
Additional flow rate adjustable from controller from 100% to 1% of maximum flow over a 5 minute period.
CO2 scrubber for CO2 control.
Descant tube for Humidity Control.
RESPIRATION & RQ MEASUREMENT
Automatic frequency of measurement, adjustable from 10 to 999 hours
OPERATION OF INTERNAL FAN
ON when control gases being added. With no gas addition, adjustable over range 1 to 299 seconds every 300 seconds.
TEMPERATURE MEASUREMENT
Probe with a typical accuracy of 0.1°C available for measuring and recording the product temperatureANALYSER CALIBRAT ION
Zero stability typically better than 0.05% over 12 months
Automatic barometric pressure compensation for span calibration
Remote calibration possible from operating panel.
Sampling port available for atmosphere sampling with a portable standard analyser and for Ethylene and volatile measurement
PRESSURE RELIEF
The flow of correction gases into the CūrPod are automatically discharged to atmosphere through a vent.
ELECTRICAL CONNECTION
One multicore cable for CAN data connection and 24v operational power. Connector & wall mounted termination box provided with each LabPod.
CENTRAL OPERATION PANEL
5.7inch touch screen display. Capacity for up to 32 CūrPod connections. 24v power supply for the system included in Panel.
Additional power supply needed for greater than 16 CūrPods. The controller has a standard Ethernet connection with a dedicated IP address. Remote client and PC software provided for PC operation.
Continuous readout of gas and temperature and operational status. Access to all control settings. Remote analyser calibration protected with a passcode. Settings for empty volume and product weight for respiration rate calculations
DATA COLLECTION
O2, CO2 and temperature recorded every hour together with most recent RQ and respiration results. Results stored on CF card in PLC and on hard disk of connected PC. Can be displayed on PC in Graphical and tabular formats and exported in various formats including Excel, Word and pdf.
LEAKTIGHTNESS
Oxygen at typically 1% in a static LabPod (no produce, no correcting gas) will remain within 0.1% O2 over a period of 24 hours.
DIMENSIONS
135 x 84 x 70 cm high Weight 46 Kg. Empty volume 379L Pull down time to 2% Oxygen with N2 at 5 L/min is 4 Hours.
Capacity: 4 x RPC crates (Typical Single RPC size: 40 x 60 x 20 cm, 17 Kg capacity)
GC - Curepod
Don't Forget!
The I.C.E. team can help you source any Cannabis or Hemp production equipment that meets your needs even if that equipment is not listed on our site! Contact us at anytime to have us source your equipment and deliver to your site anywhere in the world.
Pricing
Contact the I.C.E. team for pricing. We have access to discounts in addition to cost savings based on bulk orders.
Shipping
All prices do not include applicable taxes and shipping costs. Contact Us to calculate shipping costs directly to your door
I.C.E Review
Coming Soon!
Did You Know?
Given the research findings, it is possible that Shakespeare was quite high when he wrote the romantic sonnets and other literary works that are still considered masterpieces by many people. If so, then the connection between creativity and cannabis consumption may just have gotten a bit stronger.
Team of Experts
The I.C.E. Store is proud to be partnered with many great industry professionals and services allowing us to review products, understand the needs of the global Cannabis industry and to allow us to provide unsurpassed services in the industry. Just contact us and we'll handle the rest!